在线制服黄色网亚洲视频丝袜制服|日本婷婷色色网欧川一区二区三区|网站黄一区二区无黄无码视频免费|亚洲无玛一二三区有码无码一区中文|亚洲精品国产资源黄色网站制服丝袜|蜜臀人妻一区久久依一区二区|久久久噜噜噜卡不卡无码视频|在线播放亚洲九九亚洲图色

December 22(Sunday) , 2024

Products / 產(chǎn)品資訊

username:
password:

Tower

Position:Home > Products > Tower > HR900 Series[1~10KVA]

HR900 Series

·Description

HR900 series1-in/1-out 1KVA ~ 10KVAis a new generation of (parallel redundant N+X) double transformation and frequency online UPS, which designed by power star to meet with the requirements of Chinese power grid environment and the network system of the power. System control chip with 32 bit data bus microprocessor, which has great performance and accurately and quickly detect and control all working points of UPS, with rapid response to the change of external environment, ensuring the high reliability of the products; for China power grid environment of professional design makes the UPS input voltage, of which the frequency range is extremely wide; advanced times pressure type PFC technology makes the UPS input power factor close to 1; online double conversion structure design makes the UPS output frequency and voltage stabilizing, filtering noise, not affected by power fluctuation interference of sine wave power; when the power is cut or restored, there is no switching time for the UPS output; the digital control technology is used to realize the parallel expansion and parallel redundant function, and provide users with the power source planning flexibility and better security protection; intelligent battery management technology greatly prolongs the service life of the battery; LED+LCD display allows users to intuitively understand UPS running state and loading condition; Clients can use the PC RS232 interface through the UPS real-time understanding of work status, historical records and automatic switch machine; SNMP cards and related software can realize unattended and remote network monitoring and management, adapting to advanced network system using.

·Features

■Adopt advanced DSP digital control technology, which makes UPS performance stable and quality reliable;
■Adopt digital power factor correction technique (PFC), so that the input power factor is close to 1, reduce the power waste, completely eliminate UPS to electric power pollution, thus realizing the real green power;
■Achieve almost 90% of the full load operation efficiency, could reduce UPS power loss, and save expenditure of charge of electricity which is effective for you;
■Provide the best power for loading equipment by outputting low distortion sine wave power, either in AC mode or battery mode;
■The wide input voltage and frequency range, avoid grid voltage changes, frequently switch to battery power supply, and adapt to the harsh environment of the power region;
■The city electrical abnormalities (including electric power or the electric voltage is too high, too low, or frequency exceed the standard) or electricity is restored, the UPS output without switching time, meet the high standards and high demands of sophisticated equipments to the UPS power supply;
■Starting from the diagnosis functions, avoiding pitfalls and UPS may trigger failure risks;

■Comprehensive protection function, with the AC input, over and under-voltage protection, rectifier over and under-voltage protection, output, output under voltage protection, overload, short circuit protection, over temperature protection inverter multi function s protection in one, greatly guarantee the stability and reliability of the system;
6KVA-10KVA can realize the N+X redundant functions, automatic load sharing, if one UPS fails, will automatically cut off the output, the load from the remaining UPS will provide power supply and parallel redundancy to improve the reliability of UPS system, of which the UPS is the mainstream technology in the field;
■The bypass function, when the UPS failure occurs, power to the load through bypass uninterruptedly, and provides a sound and light alarm;
■By the operation panel alarm silencing function button, can avoid unnecessary loud sound, when the battery voltage is low or the UPS exception occurs, the alarm can be automatically restored;
■The DC cold start function, unique DC (DC) boot, the public power is interrupted when the battery for start UPS directly, giving full play to the UPS emergency functions, making the use of which more convenient and reliable;

■The overload or inverter failure conditions, UPS will convert to bypass state, by the power supply; if the overload condition is removed, UPS will be automatically transferred back to the inverter power supply state;
■The intelligent unattended function, when the UPS in electric power or electric under-voltage or ultra high pressure and enable battery mode power supply, ultimately for the battery under-voltage automatic protection shutdown; when the utility power is restored, the UPS first detection voltage, frequency is within the normal range, when the electric voltage, frequency in the normal range, UPS since the start of the power to the load; when the electric voltage, frequency is not in the normal range, UPS is only starting charger to charge the battery, until the voltage, frequency recovered to within the normal range or charging of the battery voltage reaches a predetermined value UPS to start trend load power supply;
1KVA-3KVA zero line reversal detection function, avoid UPS input power zero line plug;
■To prevent false triggering function, each key has a delay function, only the sustained one reaches a predetermined time value, the key will play a role of corresponding functions, in order to prevent the misuse of shutdown, shutdown key predetermined time value is set for the longest one;
1KVA-3KVA with surge voltage protection function (TVSS), ensure the telephone, fax, Modem, network and other communications from UPS surge, the lightning disturbance (unique);
■With remote power function (EPO), when accidents happened, people can quickly turn off UPS;
■The battery protection function, effectively prevent the battery discharge / charging battery might cause permanent damages and short life expectancy, battery under-voltage warning function can inform the user relevant treatment is carried out, and by setting the regularly self-checking, early detection of battery failure, avoid loss;
■Intelligent battery management function (ABM) technology, effectively extending the service life of the battery, reduce the number of battery maintenance. The use of advanced automated conversion of constant current and constant voltage charging technology, the maximum activation cell, save the charging time, thereby prolonging the service life of the battery;

■In the normal city, no battery is needed to start the UPS, both to meet the user's demand of emergency rescue, and to be in maximum repair damage cell;
■The long-acting type in the city power under pressure or high pressure and enabling battery mode power supply, the built-in high current charger and battery connected in parallel to the UPS provides DC current, thus prolonging the standby time UPS, UPS in half, 1 times longer than that of standby time;
■The configuration manual repair bypass, as long as the UPS is to repair its mode, it can be in continuous supply for a load under the condition of on line repair;
■The selection of isolation transformer, the input and output of which are isolated, which provide the user with isolated protections;

■Can be paired with generator uses, use time more extended, and effectively ,remove the generator to generate power for the load side, and provide clean, safe, stable power supply;
■The centralized control panel can provide rich information (LED/LCD panel display panel optional), LED communication interface in a graphic display of UPS power supply, inverter, battery powered, bypass power supply, UPS fault, battery capacity, load capacity of working condition; LCD liquid crystal display interface to the user accurately display the current, voltage, UPS frequency, fault information, work environment, work conditions and load conditions, so that the various parameters of UPS stick out a mile display interface in the LCD, which can master the UPS power supply quality and changes of environment at any time;

■The adoption of advanced technology for anti electromagnetic interference, electromagnetic interference and radio frequency interference, of which is in line with international standards EN50091-2 and IEC61000-4 series standard design, and has very good electromagnetic compatibilities, with minimizing or even eliminating the equipments caused by electromagnetic interference;

■ UPS between PC and UPS through RS232 interface, multiple functions of monitoring, real-time understanding of the working state of UPS, historical records and automatic switch machine, simplify the network management, improve the system reliability;

■The configuration of the SNMP card and monitoring software, using TCP/IP, SNMP, HTTP, TFTP, through the WEB browser, to achieve in the Internet/ Intranet remote monitoring, real-time status query, information management, remote control, parameters settings, user managements, historical data query comprehensive monitoring and management functions, and can send short message or Email to users to alarm through mobile phones or system administrators, support for the operating systems: Windows 7, Unix, Linux etc.

·Technical Specifications
Model
HR910S
HR910H
HR920S
HR920H
HR930S
HR930H
Capacity
1KVA/900W
2KVA/1800W
3KVA/2700W
Input and output
1-in/1-out
Input
Cold start
support the battery cold start, the default frequency is 50HZ(settable)
Input voltage
50%~125%(220VAC/230VAC/240VAC)
80%~125% at 100% rated load
70%~125% at 85% rated load
60%~125% at 75% rated load
50%~125% at 60% rated load
Voltage switching point
Low voltage switching 110VAC

Low voltage recovery 121VAC

High voltage switching 288VAC
High voltage recovery 281VAC
Input currenton
4.8A
9.6A
14.4A
Input frequency
40~70Hz
Power factor
≥0.97
Output
Rated voltage
220VAC
Output waveform
sine wave
Power factor
0.9
Voltage regulation
±1%
Dynamic response
≤5% (0% - 100% -0%)
Dynamic recovery
≤10ms (0% - 100% -0%)
Voltage distortion
≤1% THD, linear load
≤5.5% THD, nonlinear load
≤5% THD, nonlinear load
≤5% THD, nonlinear load
Frequency adaptive
settable
Trace range
±5Hz acquiescent
Trace velocity
0.5~5Hz/s,2 Hz/s acquiescent
Battery mode
(50±0.1) Hz acquiescent
Current
4.3A
8.6A
13.5A
Overload capacity
(Online mode)
105%~130%: 1m then switch to bypass
150%: 30s then switch to bypass
Overload capacity
(battery mode)
105%~130%:maintain 10s then shutdown
150%:maintain 5s then shutdown
Overload capacity
(bypass mode)
<130%: normal
130%~150%:1m then shutdown
150%~180%:5s then shutdown
Load crest factor
3:1(Max)
System
Switching time
0ms (main switch to battery)
2ms(inverter switch to bypass)
EMI/EMC
IEC/EN 62040-2:2006 C3
EMS
IEC/EN 61000-4-2:2009 B (ESD)
IEC/EN 61000-4-3:2006 +A1:2008 +A2:2010 A (RS)
IEC/EN 61000-4-4:2004+A1:2010 B(EFT)
IEC/EN 61000-4-5:2006 B(Surge)
IEC/EN 61000-4-6:2009 A(RF)
IEC/EN 61000-4-8:2010 A(Magnetic Field)
IEC/EN 61000-4-11:2004 A(VD)
IEC/EN 61000-2-2:2002 A(LF)
Efficiency
Main mode with
batteries charged
when 100% rated load, it is 86%
when 50% rated load, it is 87%
when 100% rated load, it is 88%
when 50% rated load, it is 91%
when 100% rated load, it is 88%
when 50% rated load, it is 90%
ECO mode
94%
97%
97%
Battery mode
when 100% rated load, it is 83%
when 50% rated load, it is 84%
when 100% rated load, it is 87%
when 50% rated load, it is 88%
when 100% rated load, it is 87%
when 50% rated load, it is 89%
Noise
(1m far away)
when <60% rated load, it is <45dB
when >60% rated load, it is <50dB
when <60% rated load, it is <50dB
when >60% rated load, it is <55dB
when <60% rated load, it is <50dB
when >60% rated load, it is <55dB
Battery
Type
maintenance-free lead-acid batteries
Model
12VDC/7Ah
depending on the external battery
12VDC/7Ah
depending on the external battery
12VDC/7Ah
depending on the external battery
Quantity
3
6
8
Direct voltage
36VDC
72VDC
96VDC
Backup time
80%load
6m
depending on the external battery
80%load
6m
depending on the external battery
80%load
5.5m
depending on the external battery
Low-voltage battery
33VDC~35VDC,changed by load factor
66VDC~70VDC,changed by load factor
88VDC~94VDC,changed by load factor
Charger
Charging voltage
floating charge:41VDC/ equalized charging:42VDC
floating charge:82VDC/ equalized charging:84VDC
floating charge:109VDC/ equalized charging:112VDC
Maximum charging current
1A
4A/8A
1A
4A/8A
1A
4A/8A
Charging time
8h up to 90%
depending on the external battery
8h up to 90%
depending on the external battery
8h up to 90%
depending on the external battery
Leakage current
<1mA
Display and alarm
Display
LED+LCD
Battery discharge
sounds every 2m
Low-voltage battery
sounds every 6s
Overload
persistent sound
Abnormal input voltages (including phase sequence reversed, unearthed)
sounds every 2m
Alarm
sounds every 6s
Fault
persistent sounding
Interface
RS232
support background software through the standard cable
SNMP(option)
monitoring machine through the network monitoring machine
EPO
emergency shutdown
Input
IEC C14
14.4A
Output
6*IEC C13
14.4A
Option
IC card
pluggable DB9 dry contact
USB
USB interface of type B
SNMP
pluggable
Environment
Temperature
0~40℃
Humidity
0%~95%
Altitude
<1500m
Physical characteristic
Size(mm)
(W*D*H)
440*430*86
(2U)
440*430*86
(2U)
440*480*173
(4U)
440*480*86
(2U)
440*480*173
(4U)
440*480*86
(2U)
Packing size (mm)
(W*D*H)
580*565*250
580*565*250
580*660*335
580*615*250
580*660*335
580*615*250
Weight (kg))
12
6
21
10.5
25.6
11.5
Gross weight (KG)
13
7
22
12
27
13
Colour
Black



Model

HR960H

HR9010H

Capacity

6KVA/5400W

10KVA/9000W

Input and output

1-in/1-out

Input

Cold start

support the battery cold start, the default frequency is 50HZ(settable)

Input voltage

50%125%(220VAC/230VAC/240VAC)

80%125% at 100% rated load

70%125% at 85% rated load

60%125% at 75% rated load

50%125% at 60% rated load

Voltage switching point

Low voltage switching 110VAC/115VAC/120VAC

Low voltage recovery 116VAC/122VAC/127VAC

High voltage switching 275VAC/288VAC/300VAC

High voltage recovery 268VAC/279VAC/291VAC

Input currenton

All surpot

Input frequency

4070Hz

Power factor

≥0.99

Output

Rated voltage

220/230/240VAC

Output waveform

sine wave

Voltage regulation

±1%

Dynamic response

≤5% (50% - 100% -50%)

Dynamic recovery

≤15ms (0% - 100% -0%)

Voltage distortion

≤1% THD,linear load

≤5% THD,nonlinear load

Frequency adaptive

settable

Trace range

±3Hz acquiescent

Trace velocity

0.55Hz/s,2 Hz/s acquiescent

Battery mode

(50±0.05)Hz acquiescent

Current

27A

45A

Overload capacity

(Online mode)

110%: 10m then switch to bypass

130%: 1m then switch to bypass

150%:30s then switch to bypass,1m then shutdown

Overload capacity

(bypass mode)

<110%: 10m then shutdown

>115%:10s then shutdown

Load crest factor

3:1Max

Power factor

0.9

System

Switching time

Main road cut battery 0ms, cut inverter bypass 0ms

Repair bypass

Standard

EMI/EMC

IEC/EN 62040-2:2006 C3

EMS

IEC/EN 61000-4-2:2009 B (ESD)

IEC/EN 61000-4-3:2006 +A1:2008 +A2:2010 A (RS)

IEC/EN 61000-4-4:2004+A1:2010 B(EFT)

IEC/EN 61000-4-5:2006 B(Surge)

IEC/EN 61000-4-6:2009 A(RF)

IEC/EN 61000-4-8:2010 A(Magnetic Field)

IEC/EN 61000-4-11:2004 A(VD)

IEC/EN 61000-2-2:2002 A(LF)

Efficiency

Main mode

92%

ECO mode

97%

Battery mode

91%

Noise

(1m far away)

when <70% rated load, it is <48dB

when >70% rated load, it is <58dB

when <70% rated load, it is <48dB

when >70% rated load, it is <60dB

Battery

Type

maintenance-free lead-acid batteries

Number

1x16x12V

Backup time

depending on the external battery

Low-voltage battery

(176±3)VDC

Charger

Charging voltage

(220±1%)VDC

Maximum charging current

5A

Charging time

depending on the external battery

Leakage current

<2mA

Display and alarm

Display

LED+LCD

Battery discharge

sounds every 1s

Fault

persistent sounding

Interface

EPO

emergency shutdown

RS232

support background software through the standard cable

USB(option)

support background software through the standard cable

SNMP(option)

monitoring machine through the network monitoring machine

Input

IEC C14

IEC C20

Output

6*IEC C13

6*IEC C13+1*IEC C19

Option

ECO

Economic model

Dry contact

pluggable

parallel operation

3

battery pack

16 battery box

USB

USB interface of type B

SNMP

pluggable

Environment

Temperature

040

Storage temperature

070

Humidity

0%95%

Altitude

In 1000M

Standard

Safety standard

EN62040-1

EMC

EN62040-2,EN61000-4-2EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6

Produce

YD/T1095-2018

Physical characteristic

Size(mm)

(W*D*H)

438*130*680

Weight(kg)

21

23

Colour

Black

Products shall be subject to any changes without additional notices. The pictures are for reference only. Please adhere to the original products in case of any mistake!
?
尖扎县| 柳河县| 红桥区| 长乐市| 庄河市| 西平县| 巩留县| 北宁市| 营山县| 龙山县| 遂溪县| 凤山县| 大悟县| 虹口区| 怀安县| 九江县| 楚雄市| 古浪县| 阿城市| 全椒县| 遂平县| 县级市| 万安县| 高阳县| 两当县| 临夏市| 叙永县| 中卫市| 浦县| 鹤壁市| 邵东县| 依安县| 林州市| 榕江县| 阜新| 游戏| 涿鹿县| 综艺| 璧山县| 周宁县| 乐清市|